5. Do not place the unloaded equipment in water piles or wet places.
3. Installation Site
Enough space should be reserved for operation to ensure a level ground and a good
environment. It is forbidden to be placed in places containing corrosive gases and
liquids, avoiding places with water drops, steam, oily dust, flammable and explosive
gases, floating dust and metal particles.
The ambient temperature is within the range of 0℃-40℃; the ambient humidity is
within the range of 1%-75%. Avoid close to heat sources, static electricity, strong
magnetic, so as not to interfere with the transmission of equipment; should not be
placed in places with strong light, avoid direct sunlight on the machine, affecting the
service life.
4. Power Requirements
The chassis uses a 220V/110V ± 10%/50HZ standard power supply, and the air pump
uses a two-phase 220V ± 10% (110V optional) to ensure stable power supply; If the
power supply is unstable and the single-phase voltage fluctuation range exceeds the
power supply requirements, it is recommended to install a voltage stabilizer; Avoid
using the same power supply as other high-power or interfering electrical appliances
to maintain power stability; Equipped with an air switch of no less than 16A, the
power supply has good grounding protection or independent grounding.
5. Air Compressor
1. Self provided air pump
One self-contained small air compressor with a pressure of 0.7 Mpa and an air storage
tank capacity of over 8 liters.
6. Machine Installation
1. Insert the machine plug into the power supply
    "