FastCOLOUR-ONE Printer UV and Non-UV Wiring Connections
1. Chiller Cable
Connect Chiller Cable for UV printing.
Yellow wire connects to the middle section,
Blue and Brown on the side.
UV-Light should be ON behind the carriage,
switch Blue/Brown can switch lighting
order. For a single LED, installing on LEFT is
recommended.
(Brown)
UV1+
(Yellow)
GND-
(Blue)
UV2+
For Non-UV, remove the chiller and chiller
cable.
2. Heater
For UV Printing, turn OFF of Heater in
Setting,
also remove the header/fan installed in front.
For Non-UV Printing, turn ON Heater is recommended.
    "