EasyRoute Control Panel is based on Weihong NK105 CNC Integrated Machine OEM http://am.co.za/router/panel
上海维宏电子科技股份有限公司
Weihong Electronic Technology Co., Ltd.
modification.
Direction of X
· Positive
Negative
5.5. System Start-up
Fig. 5-4 Selection dialog
The system interface is as shown in Fig. 5-5 after power on.
Booting the system...
Fig. 5-5 System start-up interface
After system boot-up, “Back to REF. Point” will be prompted firstly, as shown in Fig. 5-6. Please
press [ESC] to cancel this operation. You need to adjust the following related parameters: port polarity
(see chapter 6.3), pulse equivalent (see chapter 6.1), axial output direction (see chapter 6.1) and
machine stroke (see chapter 6.2) before executing returning to backing to reference point.
Back to REF.
Point?
OK
ESC
Fig. 5-6 Prompt for backing to reference point at boot-up