Duxe.ru VICSION VS500 91
Fu.14 Inverter overheat
1. Wind hole is blocked
2. Environmental temperature is too high
3. Fan is damaged
1. Clear air duct or improve the air condition.
2. Improve ventilation condition or decrease
carrier frequency.
3. Replace fan.
Fu.15 Reserved
Fu.16
External equipment
failure
There is signal input on the peripheral. Equipment fault Check the signal source and the pertinent
input terminal of Inverter
equipments.
Fu.17 Reserved
Fu.18 Reserved
Fu.19 Reserved
Fu.20
Current
checking error
1.The current detecting equipment or circuit is
damaged
2.Auxiliary power supply has problem
Contract Us
Fu.21
Temperature sense
occur faults
1. Signal line of temperature is poor contact
2. Temperature sensor is damage.
1. Check jack
2. Contract Us
Fu.22-
Reserved
Fu36
Fu.37
External equipment
failure
Fu.38
External equipment
failure
Fu.39
External equipment
failure
U-phase current output phase lack or unbalance
V-phase current output phase lack or unbalance
W-phase current output phase lack or unbalance
Inspect U-phase and motor connecting wire
Inspect V-phase and motor connecting wire
Inspect W-phase and motor connecting wire
Fu.40
Inner data of storage
is wrong.
Read and write errors of the control parameter
Contract Us
8.2 Fault record inquiry
This series inverter records the codes of faults occurring in the latest 6 times and the inverter output parameters of the
last fault, through query of which can help find out the fault reasons.
The fault information and status monitoring parameters are stored uniformly, and please query the information by
referring to the keyboard operation method.
Monitor Item
d-26
d-27
d-28
d-29
d-30
d-31
Contents
First fault record
Second fault record
Third fault record
Fourth fault record
Fifth fault record
Sixth fault record
Monitor Item
d-32
d-33
d-34
d-35
d-36
d-37
Contents
Output frequency of last fault
Setting frequency of last fault
Output current of last fault
Output voltage of last fault
DC voltage of last fault
Module temperature of last
VS500 series of general purpose inverter Duxe.ru
    "