2 VICSION VS500
2.1 Installing
2.1.1. Do not put the inverter on the combustible material.
2.1.2. E380 series inverter can’t install in the explosive ambient.
2.1.3. Do not drop other material into the inverter.
It is forbidden to disassemble and refit the inverter.
2.2 Wiring
2.2.1. It must be operated by professional worker when wiring.
2.2.2. Please be sure to turn off the power supply at least 10 min before wiring.
2.2.3. Inverter and motor must be grounded correctly.
2.2.4. Be sure to wire or inspect the inverter after power-off at least10 minutes.
2.2.5. Electron components are sensitive about static electricity, so do not drop other material in inverter or
touch the main circuit.
It is forbidden to connect an AC power supply with the U, V and W output terminals directly
2.3 Maintenance
1. Do not touch the radiator after power-off at least 10 minutes.
2. The earth terminal of inverter must be connected to ground reliably.
3. Attention Notes:
3.1. Be sure to install the inverter in a well-ventilated ambient.
3.2. The temperature at variable-frequency will be higher than at line-frequency, which is normal phenomenon.
3.3. The ordinary motor cannot run in the low speed for a long time, so user should select the special motor
for inverter or reduce the motor load under the low speed.
3.4. When the altitude is over 1000m, the inverter will be valid to decrease the rated current, and the rated
current will decrease 10% when the attitude is increased 1500m.
Be sure not to connect the output terminals of inverter with the filter capacitors and other surge
absorbers.
4 Dispose
When you dispose inverter and its parts, please pay attention to:
Capacitor: The capacitors in inverter may explode when they are burned.
Plastic: Poisonous gas may be generated when the front panel is burned, please pay attention to the waste gas
when the plastic parts are burned.
Method: Please dispose inverter as industry rubbish
VS500 series of general purpose inverter Duxe.ru
    "