Parameter
Type
Duxe.ru VICSION VS500 85
Code
F3.9
F3.10
F3.11
F3.12
F3.13
F3.14
F3.15
F3.16
F4.0
F4.1
F4.2
F4.3
F4.4
F4.5
F4.6
F4.7
F4.8
F4.9
F4.10
F4.11
F4.12
F4.13
F4.14
F4.15
F4.16
F4.17
F4.18
F4.19
F4.20
F4.21
F4.22
Name
Frequency reach the
checkout amplitude
FDT setting 1
FDT output delay
time 1
FDT setting 2
FDT output delay
time 2
Over-loading alarm
level
Over-loading alarm
delay time
Reserved
Reserved
Start frequency
Start frequency
duration
Stop mode
Initial freq. of DC
braking
when stopping
Waiting time of DC
braking
when stopping
Action time of DC
braking
when stopping
DC braking current
when stopping
Running threshold of
zero freq.
Return different of
zero freq
FWD jog frequency
Acc torque level
Motor over-lode
protection coefficient
Automatic voltage
regulationAVR
Energy-saving
running
Intensify of
energy-saving
running
Dead time of
FWD&REV
Acceleration time 2
Deceleration time 2
Acceleration time 3
Deceleration time 3
Acc time 4/Jog Acc
time
Dec time 5/Jog Dec
time
Probable Causes
0.020.00 Hz
0.0the upper limit freq.
0.0200.0 Sec
0.0the upper limit freq.
0.0200.0Sec
50200(%)
0.020.0 Sec
0.010.00 Hz
0.020.0 Sec
0Decelerate mode 1Uncontrolled stop
0.050.00 Hz
0.05.0 Sec
0.020.0 Sec
0.0100(%)
0.0100.00 Hz
0.050.00 Hz
0.0the upper limit freq.
110200(%)
50110(%)
0Invalid 1Dynamic valid
2Static valid 3Deceleration invalid
0Invalid 1Valid
3090
0.05.0 Sec
0.16000 Sec
0.16000 Sec
0.16000 Sec
0.16000 Sec
0.16000 Sec
0.16000 Sec
Min.
Unit
0.01
0.01
0.1
0.01
0.1
1
0.1
0.01
0.1
1
0.01
0.1
0.1
0.1
0.01
0.01
0.01
1
1
1
1
1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Factory
Value
5.00
2.00
0.1
10.00
2.0
110
2.0
0.5
0.0
0
3.00
0.1
2.0
30.0
0.0
1.00
4.00
150
110
0
0
60
0.0
0.8
0.8
Modification
Limited
VS500 series of general purpose inverter Duxe.ru
    "