Parameter
Type
Duxe.ru VICSION VS500 83
Code
F3.0
F3.1
F3.2
F3.3
F3.4
F3.5
F3.6
F3.7
Name
Min.
Probable Causes
Unit
0Control terminal is idle
Function selection of 1Multi-speed control terminal 1
input terminal 1
1
(0~35)
2Multi-speed control terminal 2
3Multi-speed control terminal 3
4Wobble freq. is valid
Function selection of
input terminal 2
5State of wobble freq. reset
1
(0~35)
6FWD jog control
7REV jog control
8Acc& Dec time selection terminal 1
Function selection of
input terminal 3
9Acc& Dec time selection terminal 2
1
(0~35)
10Freq. setting channel selection 1
11Freq. setting channel selection 2
12Freq. setting channel selection 3
Function selection of
input terminal 4
13Freq. is controlled gradually increase
1
(0~35)
(UP)
14Freq. is controlled gradually decrease
(DW)
Function selection of 15UP-DW freq. clear
input
16Uncontrolled stop control
1
terminal 5 (0~35)
17Fault signal of peripheral equipment
input
18Three-line mode running control
19DC braking control
20Inner counter clear
21Inner counter timer
22PLC running valid
Function selection of 23PID running valid
input
24Internal timer trigger terminal
1
terminal 6 (0~35)
25PLC state reset after stopping
26Multi-speed control terminal 4
2730: Reserved
31: Coil diameter reset
32: Initial coil diameter selection terminal 1
33: Position switch
34: Disconnection proximity switch
35: Disconnection reset / Brake release
0: Inverter in running
1: Frequency reaching
2: Freq. level detection signal (FDT)
Output terminal OC1 3: Over-loading alarm
1
4: External fault halt
5: Output frequency reaches the upper-limit
6: Output frequency reaches the lower-limit
7: Running in zero speed
8: Under voltage shutdown
9: PLC stage is end of run
Output terminal OC2 10: PLC periodic is end of run
1
11: Internal timer arrives regular time
12: Setting value of counter arrival
13: Designated value of counter arrival
Factory
Value
1
16
3
6
34
35
2
22
Modification
Limited
VS500 series of general purpose inverter Duxe.ru
    "