Duxe.ru VICSION VS500 79
7.3 Parameter table of drawing machine dedicated function ([F0.0] =0001)
The drawing machine dedicated parameter table can be used in comparison with the general parameter table, wherein,
the parameters in the shaded part are somewhat different from the parameters in the general parameter table (with
different value or definition), other parameters are identical with that defined in the general parameter table, and please
refer to the description of the general parameter table for the corresponding description and user guide.
Description of marks in the functional parameter table:
“★” means that the parameter cannot be changed during the running; “▲” means that the parameter is associated with
the inverter model.
Parameter
Type
Code
F0.0
F0.1
F0.2
F0.3
Name
Running mode
selection
Frequency input
channel / mode
selection
Frequency digital
setting
Auxiliary control of
freq. Digital setting
Min.
Probable Causes
Unit
LED bits : Running mode
0:General mode
1:Special for drawing machine
LED tens: Reserved
1
LED hundreds: Reserved
LED thousands: Reserved
0:Frequency setting by operation panel
1:UP/DW Acc and Dec control
2:RS485 interface
3:Panel potentiometer
4:External voltage signal VC1(0V~5V)
1
5:External voltage signal VC2(0V~10V)
6:External current signal CC(0~20mA)
7:External pulse signal(0.0~50.0KHz)
8:Combination setting
9:External terminals
0.00~ the upper limit frequency
0.01
The first part of LED(form right to left):
0:Setting freq. will save after power down
1:Setting freq. will not save after power
down
The second part of LED:
0:Setting freq. is to keep when stopping
1
1:Setting freq. will save in F0.2 when
stopping
2:Setting freq. is clear when stopping
The third and fourth part of LED(form right
to left):Reserved
Factory
Value
0001
2
0
0021
Modification
Limited
★