Duxe.ru VICSION VS500 77
It is used for setting some coefficients with special function in running process. Generally, user needn’t set.
The first part of LED(form right to left)Under voltage compensation intensity
The second part of LEDOver voltage inhibit intensity
The third part of LEDOver current inhibit intensity
The fourth part of LEDSelf-adapting braking torque adjust intensity
FC.5 Action function selection
Setting range0000 ~ 0111
The first part of LED(form right to left)Cooling fan control
0Cooling fan run after inverter run.
Cooling fan will stop after inverter stop. When temperature is above 40the cooling fan also will also run.
1Cooling fan will automatic run when inverter is power on.
The second part of LEDReserved.
The third part of LEDVoltage over modulation
0Invalid
1Valid
The fourth part of LEDReserved
FC.6 Auxiliary functions
Setting range00000011
The first part of LED(form right to left)Forbid to modify parameter.
0Invalid.
1Valid.
When it forbids modifying parameter is valid, [F0.18] will be invalid, if you want to get new password, please
ask for our service department. This function is used for preventing modify parameter wrongly.
The second part of LEDInput terminal effective level.
0Low level (terminals is connected)
1High level (terminals is disconnected)
The third part of LED: Reserved
The fourth part of LEDSelection of rotate speed display proportion
0: the coefficient of rotational speed display is valid
Rotational speed display=Rotational speed×Rotator speed coefficient setting (F6.11
1: the deceleration proportion is valid
Rotational speed display=Rotate speed Rotator speed coefficient setting(F6.11)
FC.7 Reserved
FC.8 Agency password
FC.9~ FC.10 Reserved
FC.11 Oscillatory inhibiting factor
FC.12 Reserved
It iFsCre.1ad3-onPlyropgaramevteerr.sion
Setting range0 ~ 9999
Setting range: 0.0~ 2.00
Range: 1600 ~ 1699
VS500 series of general purpose inverter Duxe.ru
    "