Duxe.ru VICSION VS500 71
The third part of LED: wobble freq. characteristicSee explanation about parameter F7.3
0The wobble freq. is fixed
1The wobble freq. is changeable.
The fourth part of LED: Storage characteristic of wobble freq.
0It will not save the running state of wobble freq. after power off
1It will save the running state of wobble freq. after power off
F7.1 Preset freq. of wobble freq.
F7.2 waiting time of preset freq.
Setting range0.0 ~ the upper limit freq.
Setting range0.0 ~ 6000.0s
Preset freq. of wobble freq. is running freq. before inverter is in or out wobble freq. mode.
When [F7.0]###1inverter will start and run in preset freq. of wobble freq., then run in wobble freq. mode after the
setting time of F7.2.
When [F7.0]###2 and the terminals of wobble freq. is valid (F3.0~F3.5 is 4)the inverter will run in wobble freq.
mode. When [F7.0]###2 and the terminals of wobble freq. is invalid, inverter will output preset freq. [F7.1].
F7.3 Amplitude of wobble freq.
Setting range0 ~ 50.0 %
F7.3 is rate of amplitude of wobble freq. When F7.0 is [F7.0]#0##
Amplitude of wobble freq.[F7.3] ×the upper limit freq. [F0.8] When F7.0] #1##
Amplitude of wobble freq.[F7.3] ×Preset center freq. of wobble freq. [F7.7] + External setting freq.
F7.4 Jumping freq.
Setting range0.0 ~ 80.0 %
When freq. arrives the upper limit freq., the freq. will fast decline. Or when freq. arrives the lower limit freq., the freq.
will fast ascend. Jumping freq. is amplitude, which freq. is ascending or decline. Shown as fig6-27
Actual jumping freq. = [F7.4] ×Amplitude of wobble freq. [F7.3]
F7.5 Triangular rise time
F7.6 Triangular fall time
Setting range0.1 ~ 1000.0 s
Setting range0.1 ~ 1000.0 s
F7.5 defines the running time form lower limit freq. to upper limit freq. of wobble freq., namely Acc time F7.5 defines
the running time form upper limit freq. to lower limit freq. of wobble freq., namely Dec time The sum of F7.5 and F7.6
is running cycle of wobble freq.
F7.5 and F7.6 define slope of Acc and Dec in wobble freq.
F7.7 Preset center freq. of wobble freq.
Setting range0.0 ~ upper limit freq
Center freq. of wobble freq. is central value of output freq. when inverter is in wobble freq. mode.
setting value of F7.7 and F0.1 is actual center freq.
Running process of wobble freq. is shown as fig6-28
The sum of
VS500 series of general purpose inverter Duxe.ru
    "