Adjusted setting freq
Duxe.ru VICSION VS500 69
Skip freq 2
Skip freq 1
Amplitude
accumulation of
Skip freq. 2
Amplitude accumulation of
Skip freq. 1
Fig.6-26 Skip freq
F6.9 Linear speed coefficient setting
Setting range:0.01 ~ 100.0
This parameter is used for confirming the display value of running linear speed and setting linear speed, and displaying
other value being positive ratio with the output frequency.
Running linear velocity(d.10)= [F6.9] × output frequency (d.0)
Setting linear velocity(d.11)= [F6.9] × Setting frequency (d.6)
F6.10 close-loop analog coefficient setting
Setting range:0.01 ~ 100.0
PID feedback value(d.9)= [F6.10] × actual feedback value
PID setting value(d.8)= [F6.10] × setting value
F6.11 rotator speed coefficient setting
Setting range: 0.01 ~ 10.00
It is used for rectifying the display value of rotator speed.
rotator speed(d.3)= [F6.11] × actual output rotator speed
F6.12 Monitor item selection 1 / Main display
F6.13 Monitor item selection 2 / Auxiliary display
Setting range:0 ~ 11
Setting range:0 ~ 19
This parameter is used for confirming display content of operation panel in state monitor mode.
F6.14 Query or modify parameters
It is used for getting check code to query or modify parameters.
Setting range : 0 ~ 9999
F6.15 parameter initialization
Setting range:0 ~ 3
It is used for modifying inverter’s parameters to manufacture setting.
0:Parameter initialization is off.
1:Parameter initialization is on.
Parameter F0~F9 return to manufacture setting. The following parameters can’t be initialized:
VS500 series of general purpose inverter Duxe.ru