62 VICSION VS500
F4.10 FWD jog frequency
Setting range0.0 ~ Upper limit
Jog running is special running method of inverter.
Whatever the initial state of inverter is stop or run, jog signal will be received. The transition form initial running
freq. to jog freq. is ac8 according to parameters F4.21 and F4.22
f
Jog Acc time
[F4.21]
FW D Jog
Freq.
[F4.10]
Jog Dec time
[F4.22]
Jog signal
f
FW D Jog
Freq.
[F4.10]
Jog Dec time
[F4.22]
t
Jog Acc time
[F4.21]
t
Jog signal
Fig6-19 Jog running
F4.10 FWD jog frequency
Setting range0.0 ~ Upper limit
It is used for setting permissible output level of torque current under motor acceleration state.
The restriction on torque level is set by F4.11. It is percentage of rated current of inverter. For example, F4.11 set
150% that means the max output current is 150 percentage of rated current.
When output current of inverter is beyond setting value of F4.11, inverter will prolong Acc/Dec time to inhibit output
current in setting value of F4.11. Shown as fig6-20.
f
Modified Dec time
t
t
Braking
torque
level
t
t
Fig6-20 Acc torque level
VS500 series of general purpose inverter Duxe.ru
    "