the parameters F2.0 and F2.1.
5: External voltage signal VC2
Running frequency is set by external voltage signal VC2. (VC2 is form 0.0 to 10.0V) Please set the VC2 referring to
the parameters F2.2 and F2.3.
6: External current signal CC
Running frequency is set by external current signal CC. (CC is form 0.0 to 20.0mA) Please set the CC
referring to the parameters F2.4 and F2.5.
7: External pulse signal
Running frequency is set by external pulse signal. (It is form 0.0 to 350.0 KHz, and the amplitude
accumulation is form 5 to 30V) Please set the pulse signal referring to the parameters F2.6 and F2.7.
8: Combination setting
Running frequency is set by linear combination of each channel, and combination mode is decided by parameter
F02.12.
9: External terminals
External terminals set input channel of frequency. And it can be set by parameters F3.0~F3.5.
Freq. Setting terminal 3
0
0
0
0
1
1
1
1
Freq. Setting terminal 2
0
0
1
1
0
0
1
1
Freq. Setting terminal 1
0
1
0
1
0
1
0
1
Freq. Setting channel
Frequency setting by operation panel
UP/DW Acc and Dec control
RS485 interface
Panel potentiometer
External voltage signal VC1
External voltage signal VC2
External current signal CC
External pulse signal
F0.2 Frequency digital setting
Setting range:0.0 ~ the upper limit frequency
When F0.1 is 0, Frequency digital setting controls output frequency of inverter. In normal monitor state, user
can use the key
and to modify this parameter.
As for F0.1 is 1 or F0.1 is 2, the frequency will save in parameter F0.3 after power off, if F0.3 is 00#0
F0.3 Auxiliary control of freq. digital setting
Setting range:0000 ~ 0021
It is used for making sure that the frequency is set under the stopping or power off situation. When F0.1 is 0,
1 or 2, set parameter F0.3 to ensure that setting freq. is or not be saved in F0.2. The first part of LED(form right to
left):
0: Inverter will run in setting freq. that is storage in F0.2 after stopping
1: Setting freq. will lost after stopping. And inverter will run in 0.0Hz when restarting
The second part of LED(form right to left):
0:Setting freq. is kept when stopping
1:Setting freq. will save in F0.2 when stopping
2:Setting freq. is cleared when stopping
The third and fourth part of LED(form right to left):Reserved.
VS500 series of general purpose inverter Duxe.ru