34 VICSION VS500
Function Code
Name
Restart after power
F4.26 down setting
F4.27
F4.28
Waiting time of restart
after power
REV jog frequency
F5. 0
Multi-speed running
mode
F5.1
F5.2
F5.3
F5.4
F5.5
F5.6
F5.7
F5.8
F5. 9
F5.10
F5.11
F5.12
F5.13
Multi-speed frequency 1
Multi-speed frequency 2
Multi-speed frequency 3
Multi-speed frequency 4
Multi-speed frequency 5
Multi-speed frequency 6
Multi-speed frequency 7
Multi-speed frequency 8
Multi-speed frequency 9
Multi-speed frequency
10
Multi-speed frequency
11
Multi-speed frequency
12
Multi-speed frequency
13
Setting range
The first part of LED
0Invalid 1Valid
The second part of LED
0Routine mode
1Detect speed and restart mode
The third and fourth part of LEDReserved
0.010.0 Sec
0.0the upper limit freq.
The first part of LED(form right to left)Simple
PLC selection
0Simple PLC is invalid. 1Simple PLC is valid
2Simple PLC is conditional valid
The second part of LEDSimple PLC running
mode selection
0Single loop mode
1Single loop and stop mode
2Continuous loop mode
3Continuous loop and stop mode
4Keep the end value
5Keep the end value and stop mode
The third part of LED
0Restart from the first stage freq.
1Restart from running freq., which is
saved before running is break
2Restart from setting freq. when running
is break.
The fourth part of LEDPLC save state
0Non-save after power off
1Save after power off
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
0.0the upper limit freq
Minimum
Setting
1
0.1
0.01
1
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
Manufacture
Setting
0010
0.5
10.00
0000
35.00
15.00
3.00
20.00
25.00
30.00
35.00
40.00
35.00
15.00
3.00
20.00
25.00
Modify
Limit
VS500 series of general purpose inverter Duxe.ru
    "