- You are here:
- AM.CO.ZABuythisCNC Utilities Homepage
- EasyRoute-CNC-Router
- Component Manuals
- VICSION VS500 Inverter Manual.pdf
- Page 34 of 113
30 VICSION VS500
Function
Code
F2.10
F2.11
F2.12
F2.13
F2.14
F2.15
F2.16
F2.17
F2.18
Name
Setting range
Characteristics selection
of input channel
External freq. set time
constant
of filtering
Combination setting
mode
Analog output selection
(AO1、AO2)
The lower limit of
analog
output AO1
The upper limit of
analog
output AO1
The lower limit of
analog
output AO2
The upper limit of
analog
output AO2
Reserved
The first part of LED (form right to left) :
(VC1channel)
0: positive characteristics
1: Negative characteristics
The second part of LED:(VC2 channel)
0: positive characteristics
1: Negative characteristics
The third part of LED:(CC channel)
0: positive characteristics
1: Negative characteristics
The fourth part of LED:(pulse channel)
0: positive characteristics
1: Negative characteristics
0.01~1.00 Sec
Refer to the explanations about F2.12
The first part of LED (form right to left):
AO1output
0:Output freq.
1:Output current
2:Output voltage
3:Rotate speed of applied motor
4:PID setting
5:PID feedback
The second part of LED:AO2 output
0:Output freq.
1:Output current
2:Output voltage
3:Rotate speed of applied motor
4:PID setting
5:PID feedback
The third and fourth part of LED:Reserved
0.0~[F2.15]
[F2.14]~12.0
0.0~[F2.17]
[F2.16]~12.0
Minimum Manufacture Modify
Setting Setting
Limit
1
0000
★
0.01
0.10
1
0
1
0010
0.1
0.0 V
0.1
10.0 V
0.1
2.0 V
0.1
12.0 V
VS500 series of general purpose inverter Duxe.ru