28 VICSION VS500
F0. 17
Carrier wave
characteristics
Function Code
Name
F0. 18
Parameter
write-protection
F1. 0 Type of V/F Curve
F1. 1
F1. 2
F1. 3
Torque Boost
Torque boost pattern
Basic running frequency
F1. 4 Max output voltage
F1. 5
F1. 6
F1. 7
F1. 8
F1. 9
F1. 10
F1. 11
F1. 12
F1.13
F1.14
F1.15
F1.16
F1.17
F1.18
F2.0
F2.1
V/F freq. 3
V/F voltage 3
V/F freq. 3
V/F voltage 2
V/F freq. 1
V/F voltage 1
DC braking current
when starting
DC braking time when
starting
Compensation for
slipping freq.
Droop control
Initial level of droop
control
Ending level of droop
control
Droop control mode
Reserved
VC1 input lower limit
voltage
VC1 input upper limit
voltage
The first part of LED (form right to left):
Reserved
The second part of LED:
0:Load carrier wave adjustment is invalid
1:Load carrier wave adjustment is valid
The third part of LED:
0:Heat carrier wave adjustment is invalid
1:Heat carrier wave adjustment is valid
The fourth part of LED:
0:Freq. relating carrier wave adjustment is
Invalid
1:Freq. relating carrier wave adjustment is valid
Setting range
1:Forbid to modify all parameter, except F0.2
and F0.18
2:Forbid to modify all parameter, except F0.18
Other values: all parameters are allowed to
modify
0:Constant torque curve
1:Low-freq. torque curve 1
2:Low-freq. torque curve 2
3:V/F user-defined curve
0.0~20.0(%)
0:Manual 1:Automatic
5.00~the upper limit frequency
200~500V /100~250V
[F1.7]~[F1.3]
[F1.8]~100.0(%)
[F1.9]~[F1.5]
[F1.10]~[F1.6]
0.0~[F1.7]
[F1.1]~[F1.8]
0.0~100.0(%)
0.0~20.0Sec
0~150(%)
0~100(%)
0~150(%)
10~200(%)
0:Absolute droop 1:Relative droop
0.0 V~[F2.1]
[F2.0]~5.0 V
1
Minimum
Setting
1
1
0.1
1
0.01
1
0.01
0.1
0.01
0.1
0.01
0.1
0.1
0.1
1
1
1
1
1
0.1
0.1
1110
Manufacture
Setting
0
0
▲
0
50.00
400
220
0.0
0.0
0.0
0.0
0.0
0.0
50.0
0
0
0
25
100
1
0.0
5.0 V
Modify
Limit
★
★
★
★
★
★
★
★
★