(2) Parameter inquiry and modify (eg.)
Duxe.ru VICSION VS500 23
Normal Monitor Main display: 45.00 Output freq
State
Auxiliary display: 2.3 Output current
Modify
backup
parameter
+
Parameter
Inquiry
Main display: F0.0 Function code
Auxiliary display: 0 Parameter data
+
Notes: The function code F
flushes when modifying
backup parameters
Main display: F0.2 Function code
Parameter Inquiry
Auxiliary display: 45.00 Parameter data
Give up
Modify
Continue Modify
Or Return
Main display: 45.00 Parameter data
Parameter Inquiry
Auxiliary display: 2.3 Output current
Modify
parameters
according to
+
the needs
Parameter
Modify
Main display: 50.00 Parameter data
Auxiliary display: 2.3 Output current
Memorize
parameters
modified
Main display: F0.2 Function code
Parameter Storage
Auxiliary display: 50.00 Parameter data
VS500 series of general purpose inverter Duxe.ru
    "