108 VICSION VS500
4.2 Main Specifications
1. Wiring method: RS485 point to point communication
2. Remote control distance: 1~1000m
3. Power supply: DC10~24V / 250mA
RMKB001 remote control panel requires independent DC10~24V power supply, when remote control wire length is
less than 100m, and wire resistance is less than 50Ω, please choose inverter terminal DC24V (Please refer to basic
wiring diagram C-6 and C-7).
4.3 Inverter Basic Setting
Before using remote control panel, please carefully check parameters as follows:
1. Communication setting: (F9.0 = 0014), baud rate: 9600bps, parity calibration
2. Inverter address: 0
3. Inverter response delay time: less than 10ms.
4. Master - slave mode: slave (F9.3 = 0010)
4.4 Remote control
When the inverter requires to be conducted remote start/stop control, please set the “Running command channel” of the
inverter to be “Serial port communication” mode ([F0.4] = ###2); when this mode is selected for the inverter, the
external control terminal, and the operation panel of the inverter will lose the control function.
If the operation panel of the inverter requires emergency stop function when the inverter is controlled through the
remote control panel, please set “STOP key valid for all control modes” (Running command channel [F0.4] =##12). At
this time, when the inverter is stopped through the “STOP” key on its panel, it is stopped according to the fault mode,
displaying “Fu.16”.
Please set the “Select frequency input channel/mode” parameter of the inverter as “RS485 interface” ([F0.1]=2) if
requiring to adjust or set frequency with the remote control panel, and then directly adjust the frequency with the UP or
DOWN key of the remote control panel; or, set the frequency through digital setting ([F0.2]) on the remote control
panel.
4.5 Basic Wiring
Remote control panel has two basic wiring methods, user can choose any one.
Inverter
± äƵÆ÷
RS485
CM +24V +
-
Keyboard
w¼aüÅteÌËr-®¾ty§²peå× ù
outlet
Power
GND
±InveäÆrteµÆr ÷
RS485
CM +24V +
-
Power RS485
- +24V + -
Fig. C-6 Wiring Method 1
Fig. C-7 Wiring Method 2
When the wiring length is over 100m, please separately supply power to the remote control panel, and the
24V power supply of the inverter cannot be accessed to.