5. Address Definition of Communication Parameters
Address distribution of inverter parameters
Register meaning
Register address space
Function parameter 1
Monitoring parameter
The high-order is the group-index of the function code, and the low-order is the label of the function code,
such as F1.11, and its register address is F10B
The high-order is 0xD0, low-order is the label of monitoring, such as d.12, its register address is D00C
Given by PID
Operating command 2
0x1000
0x1001
Frequency setting
0x1002
Inverter status 3
0x2000
Fault information 4
0x2001
Note:
1If EEPROM of the function code parameter is frequently written, its service life will be reduced. Some
parameters do not need to be stored under the communication mode, and only the value in RAM needs to be
modified. It only needs to change F in the register high address to 0 when writing RAM value of the functional
parameter, for example, if needing to write RAM value of F1.11, its register address shall be 010B. However, this
register address representation method cannot be used for reading the functional parameter of the inverter.
2Operating command code corresponding to the operating instruction:
Operating command code
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
0x0020
Operation command
Invalid
Forward run to start
Reversion run to start
Stop
Slave forward jog
Slave reversion jog
Jog run to stop
Slave fault reset
3Inverter status code corresponding to the indication meaning:
Inverter status code
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0011
0x0012
0x0013
0x0014
0x0015
0x0016
0x0020
Implications
Slave DC voltage is not prepared
Slave forward running
Slave reversion running
Slave stop
Slave forward jog running
Slave reversion jog running
Forward accelerating
Reversion accelerating
Instantaneous stop and restart
Forward decelerating
Reversion decelerating
Slave is under DC braking status
Slave is on fault status
4The high-order of the fault information code is 0, and low-order corresponds to the label of inverter fault code
behind Fu. for example, the fault information code 0x000C means the inverter fault code is Fu.12.
VS500 series of general purpose inverter Duxe.ru
    "