Functional Details 71
F6.03
F6.04
Start delay
Stop delay
Setting range:: 0.01~10.00
Setting range: 0.01~10.00
This group of parameters defines the cutting start delay and stop delay, which is
related to the length of the first plate and last plate.
F6.05 Reserve
F6.06 Liner cutting running mode
Setting range: 0 ~2
This parameter is used to select if it is needed to enable liner cutter function.
0: Disable cutter function
1: Liner cutter mode 1(this mode is applicable to high-speed wire mode)
2: Liner cutter mode 2 (this mode is applicable to the medium-speed wire mode)
F6.07 Forward time
F6.08 Return time
Setting range: 0~60.0Sec
Setting range: 0~60.0Sec
This group of parameters defines the forward and backward time in the next
cycle in the reciprocating mode.
F6.09 High-frequency relay start frequency
Setting range: [F6.10]~100%
F6.10 High-frequency relay disconnection frequency 1 Setting range: 0~[F6.09]
F6.11 High-frequency relay disconnection frequency 2 Setting range: 100~200%
This group of parameters is used to set the conditions for engaging or disengaging
high-frequency relay.
When the inverter’s output frequency is higher than the frequency set by [F6.09]*,
the high-frequency relay is engaged. When it is lower than the frequency set by
[F6.10], the high-frequency relay is disengaged. In the liner cutting mode 2,
when the inverter’s output frequency is higher than frequency set by [F6.11], the
high-frequency relay is disengaged.