70 Function Parameter Table
F5.06 Ratio grain
Setting range: 0.0~10.0
F5.07 Integral time
Setting range: 0.01~10.00Sec
It iFs5p.0a8rameDteerrigvraotiuvpe otifminener PID controlled. Setting range: 0.00~10.00Sec
F5.09 PID adjustment frequency range Setting range: 0 ~ 100%
This parameter is used to set the upper limit frequency to be a adjusted by PID,
which is the percentage of maximum output frequency corresponding to the
maximum PID value.
F5.10 Breakage detection lower limiting value Setting range: 0.0 ~50.0%
F5.11 Breakage detection delay time
Setting range: 0.1 ~10.0Sec
If the system’s feedback value is less than the breakage detection lower limiting
value, it is deemed that the system is at the break ge status and the system starts
detecting breakage. After the delay time, if the system is still at the breakage
status, then it is deemed that there is a breakage fault.
6.7 Special machine parameter group
F6.00 Cutting function selection
Setting range: 0000~0001H
This parameter is used to select if this inverter is used for cutter dragging or
cutting control.
0: As the dragging control
1: As the cutting control
F6.01
F6.02
Cutting length
Correction of liner speed coefficient
Setting range: 0.01~10.00
Setting range: 0.01~10.00
This group of parameters is effective for cutting control. The cutting length is the
set value of required wood length in the unit of meter. [F6.02] parameter is used
for length correction which will be done according to mechanical characteristics.
E500 Series Universal Low-Power Inverter
    "