66 Function Parameter Table
frequency, i.e. the decceleration time during runing cycle at swing frequency.
When the triangular wave ascending time is the running time from the swing
frequency lower limit to swing frequency upper limit during running at the swing
frequency, i.e. the acceleration time during runing cycle at swing frequency.
F3.31 Swing frequency center frequency setting Setting range: 0.0~[F0.04]
Swing frequency center frequency means the center value of inverter’s output
frequency at the swing frequency runing status.
See Figure 6-17 for detailed process of swing frequency running
Running frequency
Kick frequency [F3.28]
Swing frequency center frequency
Swing frequency amplitude [F3.27]
[F3.29]
[F3.30]
Time
Figure 6-17 Swing Frequency Runing Process
6.5 Communication functional parameter group
F4.00 Communication setting
Setting range: 0000 ~ 0125
This parameter is used to set characteristics relevant with communication (fratile
decimal system setting)
LED Units: Baud rate selection
0: Reserve
1: 1200bps
2: 2400bps
3: 4800bps
4: 9600bps
5: 19200bps
When serial port communication is adopted, the communication parties must
have the same baud rate.
E500 Series Universal Low-Power Inverter