Functional Details 59
F2.17
Reserve
F2.18
Automatic voltage regulation
Setting range: 0~2
The automatic voltage regulation function is for protecting inverter’s voltage
from fluctuating with input voltage fluctuation. When the grid voltage varies
greatly and it desired that the motor has comparatively stable stator voltage and
current, this function should be enabled.
0: invalid
1: Deceleration time is invalid
2: Effective
F2.19
Pairs of motor polarity
Setting range: 1~16
This parameter is mainly used to calculate motor revolution.
F2.20~F2.21 Reserve
6.4 Multi-speed and senior running parameter group
F3.00
F3.01
F3.02
F3.03
F3.04
F3.05
F3.06
Multi-speed frequency 1
Multi-speed frequency 2
Multi-speed frequency 3
Multi-speed frequency 4
Multi-speed frequency 5
Multi-speed frequency 6
Multi-speed frequency 7
Setting range: 0.0Hz ~ Upper limiting frequency
Setting range: 0.0Hz ~ Upper limiting frequency
Setting range: 0.0Hz ~ Upper limiting frequency
Setting range: 0.0Hz ~ Upper limiting frequency
Setting range: 0.0Hz ~ Upper limiting frequency
Setting range: 0.0Hz ~ Upper limiting frequency
Setting range: 0.0Hz ~ Upper limiting frequency
It is to set terminals with this parameter function code to control multi-speed
running output frequency.
F3.07 Liner speed coefficient setting
Setting range0.01 ~ 100.00
This parameter is used to set the running liner speed and display value of liner
speed. It can be also used to display other physical quantity proportional to
output frequency.
E500 Series Universal Low-Power Inverter
    "