54 Function Parameter Table
F1.22
F1.23
Reserve
Reserve
F1.24 Batter number of terminal machine Setting range: 1~100
F1.25 Specified count value
Setting range: 1~[F1.26]
F1.26 Final count value
Setting range: [F1.25]~60000
Count related to F1.24, F1.25, F1.26, which only can use external termincal X3.
Please refer to parameter [F1.10] setting as 22.
F1.27 Reserve
F1.28 Frequency input channel combination Setting range: 0~10
This parameter is only effective when the frequency input channel is set to
combined setting.
The inverter’s set frequency is determined by the liner combination of multiple
frequency input channel. See following table for the defined combination mode.
By means of combined setting, the inverter’s frequency output can be controlled
by multiple channels.
Set
value
0
Combination mode
External voltage setting + panel
setting
Set
value
1
Combined setting
External voltage setting + panel
setting + digital setting
2
Communication setting + external
voltage setting
3
Communication setting + external
voltage setting+ panel setting
4
Communication setting - panel
setting + digital setting
5
Communication setting - external
voltage setting
6
Serial setting + external voltage
setting - panel setting
8 Panel setting - digital setting
7
External voltage setting – panel
setting + digital setting
9
UP/DW frequency +external voltage
setting
10
UP/DW frequency + panel setting +
external voltage setting
E500 Series Universal Low-Power Inverter