52 Function Parameter Table
terminal outputs effective signals; otherwise, it outputs void signals.
6: Running at zero speed
When the inverter’s running command is effective and the output frequency is at
0, this terminal outputs effective signals; otherwise, it outputs void signals.
7: Under voltage stop
When the inverter’s DC side voltage is lower than the specified value, the
inverter stops running, and this terminal outputs effective signals; otherwise, it
outputs void signals.
8: Inverter fault
When the inverter stops running due to fault, it outputs effective signals; and
when the inverter runs normally, it is at void status.
9: Disconnection fault
When the inverter stops running due to disconnection fault, it outputs effective
signals; and when the inverter runs normally, it is at void status.
10: PLC cycle completion
When the inverter stops running due to disconnection fault, it outputs effective
signals; and when the inverter runs normally, it is at void status.
11: High-frequency output
When the output frequency reaches the set action frequency [F6.09], it outputs
effective signals, and when the output frequency is lower than the disconnecting
action frequency [F6.10], it outputs void signals.
12: Reaching specified count value
When the internal counter reaches the specified count value [F1.25], it outputs
effective signals, and outputs void signals when the next time of pulse is reaching.
13: Reaching final value cycle
When the internal counter reaches the final count value [F1.26], it outputs
effective signals, and outputs void signals when the next time of pulse is reaching.
14: Reserve
15: Reserve
E500 Series Universal Low-Power Inverter
    "