26: Reserve
27: Reserve
28: Splitting machine infrared signal
29: Splitting machine approaching switch signal
Functional Details 49
F1.12 Selection of input channel characteristics Setting range: 0000~ 1111H
It is used to select characteristics of external digital input:
LED UNITS: Define characteristics of X1 input channel
0: positive characteristics
1: negative characteristics
LED Tens: Define characteristics of X 2 input channels
0: positive characteristic
1: negative characteristic
LED Hundreds: Define characteristics of X 3 input channels
0: positive characteristic
1: negative characteristic
LED Kilobits: Define characteristics of X 4 input channels
0: positive characteristic
1: negative characteristic
The positive characteristic is effective when the terminal is engaged and void
when the terminal is disconnected. The negative characteristic is effective when
the terminal is disconnected and void when the terminal is engaged.
F1.13
F1.14
Output terminal OC function selection
Relay output TA/TC function selection
Setting range: 0 ~ 15
Setting range: 0 ~ 15
It is used to define the contents indicated by the collector open-circuit output
terminal OC and relay output contact. See Figure 6-8 for the internal wiring
diagram of the collector open-circuit output terminal. When the function is set to
be effective, the output is at low level, and when the function is void, the output
is at the high-resistance status.
Relay contact output: when the output function is set to be effective, the normally
open contact TA-TC is connected.
E500 Series Universal Low-Power Inverter
    "