48 Function Parameter Table
16: External fault input
When the terminal set by this parameter is engaged, it indicates that the external
equipment is faulty. At this time, in order to ensure safety of the equipment, the
inverter will lock the input and displays the external fault signal Fu.16.
17: Disconnection input
When the terminal set by this parameter is engaged, it indicates disconnection
fault of external equipments. At this time, in order to guarantee equipment safety,
the inverter will lock output, and displays the external fault signal Fu.17.
18: PLC effective
When the programmable PLC running condition [F3.17] is selected to be
effective, the external terminal defined by this parameter can enable effecting
and cut-off of PLC operation.
19: Swing frequency running effective
When the swinging frequency function condition is selected to be effective
([F3.26] =XXX1), the external terminal defined by this parameter can enable
effecting and cut-off of swing frequency running.
20: UP
21: DW
The running frequency of the inverter can be set through external terminals,
hence allowing for remote frequency setting. When the terminal is effective, the
set frequency increases or decreases at set speed. When the terminal is void, the
set frequency is maintained unchanged. When the two terminals are effective
simultaneously, the set frequency is maintained unchanged. When the UP is
effective, the frequency increases and when DW is effective, the frequency
decreases.
22: Internal counting clock
Only Terminal 3 can be as count input terminal.
23: Internal counting clock clearing
24: Reciprocating running effective
25: Terminal machine running battering effective
E500 Series Universal Low-Power Inverter