46 Function Parameter Table
F1.06
F1.07
AO output lower limit
AO output upper limit
Setting range: 0.0 V ~ [F1.07]
Setting range: [F1.06] ~ 10.0 V
Define the maximum value and minimum value of analog output AO output
signal. Refer to figure 6-7.
AO
[F1.06]
0
1
Rate
currenUt pper
limiting
frequency
Output
Output
frequency
voltage
2
Max./rate voltage Output current
Figure 6-7 Analog output content of analog output terminal
F1.08
F1.09
F1.10
F1.11
Function selection for input terminal 1
Function selection for input terminal 2
Function selection for input terminal 3
Function selection for input terminal 4
Setting range: 0 ~ 29
Setting range: 0 ~ 29
Setting range: 0 ~ 29
Setting range: 0 ~ 29
Function definition of switch quantity input terminal X1 ~ X4, which is
described as below:
0: control terminal X1-X3 are as spare terminal,X4 as PWM pulse speed
control terminal
1: Multi-speed control 1
2: Multi-speed control 2
3: Multi-speed control 3
The combination of multi-speed control terminals can be used to select
multi-speed output frequency. The frequency setting at each stage is to be
determined by the multi-speed control parameter functional group ([F3.00] ~
[F3.06]).