34 Function Parameter Table
Parameter Function
Type Code
Name
Setting Range and
Description
F5.09
PID adjustment
frequency range
0.0~100.0%
F5.10
Breakage
detection value
0.0~50.0%
F5.11
F5.12
-
F5.22
Breakage
detection delay 0.1~10.0 Sec
time
Reserve
F6.00
Cutting function
selection
0: Drag
1: Cut
Minimum Default Modifica-
unit setting tion limit
0.1
100.0
0.1
5.0
0.1
5.0
1
0
F6.01
F6.02
F6.03
Cutting length
Correction of
liner speed
coefficient
Start delay
0.100~2.000
0.100~10.000
0.01~10.00
0.001
0.001
0.01
0.700
1.000
3.00
F6.04 Stop delay 0.01~10.00
0.01 4.00
F6.05
F6.06
F6.07
Reserve
Liner cutting
operating mode
Forward time
0~2
0~60.0S
1
0
0.1
5.0
F6.08 Backward time 0~60.0S
0.1
4.0
High-frequency
F6.09
relay
[F6.10]~100%
Start frequency
1
99
F6.10
High-frequency
relay
Disconnection
frequency 1
0~[F6.09]
1
98
F6.11
High-frequency
relay
Disconnection
frequency 2
100~200%
1
120
F7.00
Control mode
selection
0V/F control
1SVC (open loop
vector) control
1
0
F7.01 Motor power
0.2~7.5KW
0.1
1.5
F7.02 Rated voltage
100~500
1
220
F7.03 Rated current
0.10~30.0A
0.01
6.40
F7.04 Rated frequency 20.0~300.0HZ 0.1
50.0
F7.05 Rated revolution 200~10000
1
1400
F7.06 No-load current 0.01~20.00A 0.01
3.00
F7.07
F7.08
F7.09
Stator resistance
Stator
inductance
Reserve
0.001~30.000Ω
0.001~10.000H
0.001
0.001
1.790
228
E500 Series Universal Low-Power Inverter
    "