Function Parameter Table 33
Parameter Function
Type Code
Name
F4.02
Local response
delay
Setting Range and
Description
0 ~ 1000ms
LED Units:
Inverter main/slave
setting
0: This inverter is a
slave machine
1: This inverter is a
main machine
Minimum Default
unit setting
1
5
Modifica-
tion limit
LED Tens: Selection
of action after
Setting of communication
F4.03
communication failure
auxiliary
0: Stop
1
function (1) 1: Maintaining
current status
0010
LED Hundreds:
Data return
selection
0: Data normal
return
1: No data return
F4.04
F4.05
F4.06
-
F4.10
F5.00
F5.01
F5.02
F5.03
F5.04
F5.05
F5.06
LED Kilobit:
Reserve
Communication
overtime 0.1 ~ 10.0 Sec
detection time (1)
Linkage setting
ratio (1)
0.1 ~ 10.0
Reserve
PID function
selection
PID set channel
PID digital
setting
PID feed
forward
enabling
Reserve
PID feedback
correction
Ratio grain
0: PID closed
1: PID enabled
0: PID Digital
setting
1: frequency input
channel setting
0.0%~100.0%
Units:
0: Void
1: Feed forward
setting ( frequency
input channel )
0~2.000
0.0~10.0
0.1
1.0
0.1
1.0
1
0
1
0
0.1
0.0
1
0
0.001
0.1
1.000
1.0
F5.07 Integral time 0.01~10.00
0.01
0.20
F5.08 Derivative time 0.0~10.00
0.01
0.0
E500 Series Universal Low-Power Inverter
    "