32 Function Parameter Table
Parameter Function
Type Code
Name
Setting Range and Minimum Default Modifica-
Description
unit setting tion limit
LED Units:
function setting
0: Swing frequency
function closed
1: Swing frequency
function effective
2: Swing frequency
F3.26
Swing frequency function
running setting conditionally
1
effective
0000
LED Tens: Center
frequency setting
0: Digital setting
1: Frequency
channel selection
F3.27
Swing frequency
amplitude
0.0~50.0%
0.1
10.0
F3.28
Kick frequency
amplitude
0.0~80.0%
0.1
0
F3.29
Triangular wave
descending time
0.1~300.0 S
0.1
1.0
F3.30
Triangular wave
ascending time
0.1~300.0 S
0.1
1.0
Swing frequency
F3.31 center frequency 0.0~[F0.04]
setting
0.1
0.0
F3.32
-
F3.34
Reserve
LED Units: Baud
rate selection
0: Reserve
1: 1200 bps
2: 2400 bps
3: 4800 bps
4: 9600 bps
5: 19200 bps
LED Tens: Data
format selection
0: No check
F4.00
Communication 1:Even parity check
setting
2: Odd parity check
1
0114 ×
LED Hundreds:
protocol selection
0: SIMPHOENIX
self-defined
protocol
1: MODBUS
communication
protocol
LED Kilobit:
Reserve
F4.01 Local address 0 ~ 30
1
1
E500 Series Universal Low-Power Inverter
    "