Chapter 5 Parameters
5.6 DO function description in detail
Ordinal Symbol
Function
0
OFF Always invalid
1
ON Always valid
2
RDY Servo ready
3
ALM Alarm
Positioning
5
COIN
complete
6
ASP Arrival speed
Electromagnetic
8
BRK
brake
Torque under
11 TRQL
limitation
Function explanation
Forced output OFF.
Forced output ON.
OFF:Servo main power supply is off; Or alarm occurs;
ON :Servo main power supply is normal,no alarm occurs.
OFF:Alarm occurs;
ON :No alarm occurs.
In position control mode
OFF:Position deviation is bigger than parameter P150;
ON :Position deviation is smaller than parameter P150.
OFF:Servomotor speed is lower than parameter P154;
ON :Servomotor speed is higher than parameter P154.
Can set polarity function,refers to the explanation of parameter P154.
OFF:Electromagnetic brake applies the brake;
ON :Electromagnetic brake releases the brake.
OFF:Servomotor torque has not reached the limit value;
ON :Servomotor torque has reached the limit value.
Torque limitation is set by parameter P064.