Ordinal
18
19
20
21
Symbol
GEAR1
GEAR2
CLR
INH
Function
Electronic
gear
switching 1
Electronic
gear
switching 2
Clear
position
deviation
Pulse input
inhibition
5.5 DI function description in detail
Function explanation
Select electronic gear for command pulse by the combination of GEAR1
and GEAR2 1~4:
GEAR2 GEAR1
Numerator of electronic gear N
0
0
1st numerator(parameterP029)
0
1
2nd numerator(parameterP031)
1
0
3rd numerator(parameterP032)
0
1
4th numerator(parameterP033)
Note: 0 indicates OFF; 1 indicates ON.
Eliminates the position deviation counter; The elimination mode is selected
by the parameter P163; The elimination of position deviation occurs in the
moment:
P163=0:CLR ON Level:
P163=1:CLR Rising edge (from OFF become ON).
OFF:Permits position command pulse to go through:
ON :Position command pulse is inhibited.