5.4 Parameter description in detail
P104 Function of digital input DI5
Range
Default
value
-2121
20
z The function plan of digital input DI5. Refer to the explanation of parameter P100.
Unit Usage
ALL
P110 Filter of digital input DI1
Range
0.1100.0
Default
value
2.0
Unit Usage
ms ALL
z This is the time-constant of DI1 input digital filter.
z The smaller the value, the quicker signal responses; the bigger the value, the slower signal responses, but
filtering ability of noise is stronger.
P111 Filter of digital input DI2
Range
Default
Unit
value
0.1100.0
2.0
ms
z This is the time-constant of DI2 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
P112 Filter of digital input DI3
Range
Default
Unit
value
0.1100.0
2.0
ms
z This is the time-constant of DI3 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
P113 Filter of digital input DI4
Range
Default
Unit
value
0.1100.0
2.0
ms
z This is the time-constant of DI4 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
P114 Filter of digital input DI5
Range
Default
Unit
value
0.1100.0
2.0
ms
z This is the time-constant of DI5 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
71
    "