5.4 Parameter description in detail
P104 Function of digital input DI5
Range
Default
value
-21~21
20
z The function plan of digital input DI5. Refer to the explanation of parameter P100.
Unit Usage
ALL
P110 Filter of digital input DI1
Range
0.1~100.0
Default
value
2.0
Unit Usage
ms ALL
z This is the time-constant of DI1 input digital filter.
z The smaller the value, the quicker signal responses; the bigger the value, the slower signal responses, but
filtering ability of noise is stronger.
P111 Filter of digital input DI2
Range
Default
Unit
value
0.1~100.0
2.0
ms
z This is the time-constant of DI2 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
P112 Filter of digital input DI3
Range
Default
Unit
value
0.1~100.0
2.0
ms
z This is the time-constant of DI3 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
P113 Filter of digital input DI4
Range
Default
Unit
value
0.1~100.0
2.0
ms
z This is the time-constant of DI4 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL
P114 Filter of digital input DI5
Range
Default
Unit
value
0.1~100.0
2.0
ms
z This is the time-constant of DI5 input digital filter. Refer to the explanation of parameter P110.
Usage
ALL