Chapter 5 Parameters
5.4.2 Parameters of section 1
P100 Function of digital input DI1
z The function plan of digital input DI1:
Range
-21~21
Default
value
1
Unit Usage
ALL
the absolute value of the parameter expresses functions; the
symbolic expresses the logic. Refer to the 5.5 sections for the functions.
z The symbolic expresses the input logic. Positive number expresses positive logic and the negative number
express the negative logic. ON is effective, OFF is invalid:
Parameter DI input signal
DI Result
Positive
Turn off
OFF
number
Turn on
ON
Negative
Turn off
ON
number
Turn on
OFF
z If set the same function for many input channel, the function results in logical 'or' relations. For example
P100 and P101 are set by 1 (the SON function), then DI1 and/or DI2 is ON, the SON is effective.
z The input function which is not selected by parameter P100~P104, namely the undefined function, results in
OFF (invalid).
P101 Function of digital input DI2
Range
Default
value
-21~21
2
z The function plan of digital input DI2. Refer to the explanation of parameter P100.
Unit Usage
ALL
P102 Function of digital input DI3
Range
Default
value
-21~21
3
z The function plan of digital input DI3. Refer to the explanation of parameter P100.
Unit Usage
ALL
P103 Function of digital input DI4
Range
Default
value
-21~21
4
z The function plan of digital input DI4. Refer to the explanation of parameter P100.
Unit Usage
ALL