Chapter 5 Parameters
P036 Input direction of command pulse
z The meanings of this parameter are:
0:Normal direction
1:Direction reverse
Range
0~1
Default
value
0
Unit Usage
P
Input signal logic of command
P037
pulse
Range
0~3
Default
value
0
Unit Usage
P
z Set the phase of the input pulse signals PULS and SIGN for adjusting the counting edge as well as the
counting direction.
P037
PULS signal SIGN signal phase
phase
0
In phase
In phase
1
Opposite phase
In phase
2
In phase
Opposite phase
3
Opposite phase
Opposite phase
z parameters needs to preserve firstly and then turn off and on the power supply.
Input signal filter of command
P038
pulse
Range
0~21
Default
value
7
Unit Usage
P
z Filter the input signal PULS and SIGN numerically. The value is bigger then the filter time-constant is
bigger.
z The maximum input pulse frequency is 500 kHz (kpps) when the setting value is seven. If the value is bigger,
the maximum input pulse frequency will reduce correspondingly.
z Filter the noise from the input signal to avoid counting mistake. Because if found the running not perfect
caused by the counting pulse, then can suitably increase the parameter value.
z parameters needs to preserve firstly and then turn off and on the power supply.
Input filter mode of command
P039
pulse I
Range
0~1
Default
value
0
z The meanings of this parameter are:
0:Filter the input signal PULS and SIGN numerically.
1:Filter the input signal PULS only and not filter the SIGN signal.
z parameters needs to preserve firstly and then turn off and on the power supply.
Unit Usage
P
64