PA-4 调整为 1、PA-22 调整为 1、PA-43 按需要调整 Adjust PA-4 to 1, PA-22 to 1 and adjust PA-43 as required
PA-40 调整为 1、PA-41 调整为 1。 Adjust PA-40 to 1 and PA-41 to 1.
西门子 802C 系统参数调整:西门子 802C 系统的参数 30130 要改为“1”。
Siemens 802C system parameter adjustment: Parameter 30130 of Siemens 802C system should be changed to ―1‖.
按以上接线图接好线后,先调整好以上参数,在系统上电,驱动器上电,打开驱动器使能,系统保持零速状态,调整驱动器
AU-Spd
(模拟量速度零偏自动调整)。调整方法为:在驱动器的第一层菜单界面找到 AU,再按 enter 一次,显示 AU-Spd,再按住 enter
不放,并保持 3 秒,就会显示 FINISH(成功),最后保村参数即可。
After wiring as per the above the wiring diagram, first adjust the above parameters, electrify the system and the driver, open the driver
enable, keep the system in zero speed state, and adjust the AU-Spd of the driver (automatic adjustment of speed bias of analog value). The
adjustment method thereof: Find AU in the first menu interface of the driver and press enter once again to display AU-Spd. Then press
down enter for 3 seconds and FINISH (success) will be displayed. Finally store the parameters.
91