Appendix 1
Siemens NC system matched for MG -1000 Series Drivers
(To match Siemens 802S/801/802S)
1. Setting requirements for driver parameters
Parameter No.
Parameter Name
Unit
5
Speed ratio gain
Hz
36
filter factor of
%
command pulse
signal
Parameter Range
50-2000
0-3
Default
150
1
Note: When a Siemens NC system is matched for the driver, PA36 should be equal to 1 and PA37 to 0;
otherwise repeated position precision will be affected.
● Where reset deviations are not uniform, appropriately increase Parameter 5 of the driver.
● Pins 36 and 9 of the CN1 interface port must be connected with the shielding layer and metal casing of the
system; otherwise reset precision will be affected.
2. Setting requirements for Siemens system parameters
Parameter No.
34040
Parameter Name
Search for Z-pulse speed
Required value
500-2000
88
    "