Figure 4.5-d Input Interface for Analog Single-ended Potentiometer
电位器 Potentiometer
伺服驱动器 Servo driver
AS+AT+AS+ or AT+
AS-AT- AS- or AT-
The input voltage of the analog value should not exceed the range of -10V-+10V; otherwise the driver will be
damaged.
The analog value has a deviation indeed, because wires and the interface circuit, etc, weaken and are interfered.
It is suggested that a cable with a shielding layer be used for connection with its both ends grounded. Parameter
PA49 can be used to set the threshold voltage (unit: rpm).
The analog value has a deviation indeed, so it must be adjusted. Parameter PA45 can be used to make
compensate for the deviation value.
Principe of Encoder Interface
4.8.1 CN1 Output Interface for Encoder Signal (from the driver to the upper computer)
Figure 4.6 CN1 Output Interface for Encoder
上位机接收 Upper computer receiving
伺服驱动器 Servo driver
42
    "