4.11.2 Laser parameters
Laser config:Single tube/pipe is optional, according to the number of laser tube manufacturers actual
configuration Settings
Laser mode:Glass tube, radio frequency laser (don't need precombustion pulse) and radio frequency
laser (need precombustion pulse) optional
Laser attenuation、Min power、Max power、Laser freq、Preginition freq:
Preginition pulse:For radio frequency (%) laser and precombustion pulse, frequency and
precombustion by precombustion pulse width configuration precombustion characteristics of the pulse.
Signal level:
Water protect:When can make water protection, the controller must be connected to water protection
circuit, the machine won't out of the light, if we do not make water to protect, don't pick up the water
protection circuit, the controller will not detect.
Laser frequency used by the control signal is used to set the laser pulse frequency, the glass tube,
generally set to about 20 KHZ, Radio frequency tube usually about 5 KHZ;Maximum/minimum power (%)
is used to set the limits of the laser power value, namely at runtime, users to set maximum power can not
be higher than the set value of maximum power, user Settings cannot under minimum power value for the
setting of the minimum power value;Use after a period of time, if the laser power attenuation, is by setting
the attenuation coefficient to fine-tuning of laser power, laser without attenuation, attenuation coefficient
of 0.
Prompt:If single laser tube is configured, it only shows a laser parameters
4.11.3 Other vendor parameters
Machine type:For the most part should choose general engraving machine, other models for a particular
model
Transmission mode:Under normal circumstances should choose "step type belt", choose other type,
control algorithm will have small change
Feed mode:A one-way/two-way optional.When for one-way feeding, do not check the coordinate, but
has been unilaterally upward;When selecting a two-way feeding, the system will check the maximum
minimum coordinates, an odd number of times to one direction, even time to another direction, first initial
direction by setting the direction of polarity to change or modify feeding the length of the positive and
negative value
Broken delay:Can be set to 0 ~ 3000 ms.After power grid, the system power supply does not
immediately reduced to 0 v, during a time delay, the power set delay value should be the actual delay
values are basically identical.If the value is set, the deflection is in power to continue carving work, a
second processing of graphics and graphics or not closed before power, or too much overlap
Enable protect:If can make this, the controller must be open protection circuit is connected, otherwise
the machine will not work
Enable blower:If want to use the outlet Wind signal layer and control the fan switch, you must make to
the parameters, otherwise, the Wind signal output to other signals
Prompt:Manufacturers in the parameter configuration parameters, such as the direction of polarity,
control mode, the types of laser and laser frequency modified four parameters, it is necessary to reset the
system, reset after the completion of the changes to take effect.