scanning the graphics depth to achieve the ideal effect.
4.10.4 Laser Dot Parameters Setting
The time for emitting laser on
one dot during the process. The
higher the value is, the darker
The interval between the dots
Dot length, for cutting dash line
Only dot at center
4.11 Vendor settings
4.11.1The motor parameters
X Y Z U axis parameters
Dir polarity:Change the direction of polarity can make the motor to the reverse direction.Modify
the goal is to make the shaft to the origin when reset,if reset when the axial direction away from
the origin,explain the polar axis direction set wrong,should be modified.
Limiter polarity:Used to set the limit of high and low level signal model,If moving axis reaches
the limit position ,enter a low level signal to the main board ,the limit should be set to a negative
polarity
Breadth:The longest distance between the axes can walk,according to the actual situation of the
machine
Home offset: If the shaft can make the hard limit protection,often should set the value of
2~5mm,if set to 0,then the axes coordinate zero run to minimum,effective,has the potential to limit
such trigger error limit protection function,emergency stop the machine,if can not manke the hard
limit protection,can set value is 0~5mm.