LFS-PM-T43 Live Focus System Operating Manual V1.3
User still can selet the check follow up to be use delayand the check followto be using
trigger.
The first operation should be careful. The following step should be noticed:
1) If the drive is servo drive, please set the parameters correctly according to the operating manual
of the servo drive.
2) Then power on the distance controller, go to the MENUSetting. Configure the parameters
correctly.
3) To check the limit switch is good or not. User can trigger the limit manually. If it work well , the
information of up limit trigger or down limit trigger will be displayed in the screen. That means
the limits are working well.
If the polarity of the limit is wrong, please check and modify the polarity of the limit in the
menu.
Then check the crash alarm is good or not. Just move the laser head or the work piece to keep
they touch each other. If there are crash alarm information displays in the screen, which means
the crash alarm is ok.
4) Press
, check the moving direction of the laser headif the direction is not the
desired direction, then modify the motor polarity.
5) Calibration. If the calibration result is good, then save the data.
6) Press trace offthe button will changed into green and the text will change into trace on.
SHENZHEN RUIDA TECHNOLOGY
25
    "