LFS-PM-T43 Live Focus System Operating Manual V1.3
2.2 4.3” Touch Screen
This distance controller is included of a 4.3touch TFT screen. The resolution is 480*272. the laser
head work status is displayed in the monitor and parameters can be modified with the monitor. the
display area is function button area, data display area, running status display area and alarm display area.
The main interface is just as the following:
Function button areatouch the buttons can enter different function control menu.
Data displayhere is used to display the detecting value of the capacitor sensor and other set
values.
Focus positionthe distance between the nozzle and the work piece.
Actual positionthe actual value of the capacitor detected.
Following errorthe error between the focus position and the actual position.
Capacitor valuethe value that the controller has detect from the capacity sensor.
Running status display the status of the laser head.
Alarm displayalarm status display. If there are several alarm triggered at the same time, user
can touch the Alarm Infoto check the alarm information in detail.
Main interface
The communication between the controller and the touch screen monitor is by RS232.
If all the electrical connections has been done correctly, when power on the controller, the monitor
of the controller will go to the main interface. If there are no error happened, that means the automatic
distance controller work well.
But if the monitor indicate that connection failed because of the cable fault or other
reasons, connect failurewill be popped up. User should check the cable and the sensor devices.
SHENZHEN RUIDA TECHNOLOGY
4
    "