6. Z-axis speed: Z-axis movement speed, the greater the value, the faster, the
range between 0 to 500, the starting mode is valid for the custom mode.
7. IP address: The system IP address number, and the computer connection will
be applied to this address number.
8. Registration code: registration code provided by the supplier, and then
enter the prompt area can be. The registration code can be developed for any
period of time. After the expiration of the system will stop using, if prompted
"registration code expired" to contact the supplier, to obtain a new
registration code to continue to use.
9. Double-headed spacing: the distance between two laser heads.
10. Track display: display graphics processing side of the trajectory, divided
into points and lines in two ways.
11. Z Axis Focus: Set the focus distance of the laser autofocus.
12. Load the parameters file: use U disk to load the upper software parameters
(please refer to the upper case software instructions)
13. System upgrade: U disk upgrade system with the current software (only for
the underlying software upgrades).
The
14. Touch screen correction: through touch screen correction to enhance the
touch sensitivity.
(See Section 2.26 for Chapter 2).
2.2.6 modify the parameters of the method
1 Modify the language class parameters
Click on
Select Chinese or English, click to change
Key
to change the state of the language class parameters.
2 Modify the numeric class parameters
Double-click the dialog box to display the digital class
options dialog box, as shown in Figure 2.11 Digital dialog box. At this point
click on the touch screen on their own numbers, clickClick Save to change the
value of the selected numeric class parameter.
61