Figure 2.5 File action item
(1) Speed ratio: Percentage of current speed, in the range of 0 to 100.
(2) Power ratio: Percentage of current power used.
(3) Total number of processing: the number of times the current document needs
to be processed, ranging from 0 to 20000.
(4) Completed: The number of times the current file has been processed, in the
range 0 to 20000.
(5) time interval: the current file multiple processing, the processing is
completed after the next processing from the beginning of the interval, in
seconds, ranging from 0 to 999 between.
(6) start mode: the beginning of the current file processing starting point,
including fixed-point, immediately, custom, origin four modes.
Fixed point: the parameter setting in the positioning point X,
positioning point Y set the parameters as the starting point of processing.
Immediately: the current location of the laser head as the starting point for
processing.
Custom: the starting point of the starting point X in the file information and
the starting point Y as the starting point of the machining.
Origin: the origin of the machine as a starting point for
processing.
(7) Start point X: Sets the coordinates of the starting point of the X axis
when the laser head is started, in the range of 0.0 to 9999.999, and is valid
when the start mode is in the custom mode.
(8) Starting point Y: Sets the coordinates of the starting point of the Y axis
when the laser head starts machining, in the range of 0.0 to 9999.999, and is
valid when the start mode is in the custom mode.
(9) docking mode: after processing the laser head docked, including the
starting point, custom, origin three modes.
Start point: After processing, the laser head stops at the starting
point X, the position set by the starting point Y.
Custom: After the processing is completed, the laser head is docked
58
    "