Fixed fire time: set the preset (fixed power) optical time.
Pre-drive 1: set the laser tube 1 pre-drive power persentage.
Pre-drive 2 ;set the laser tube 2 pre-drive power persentage.
The max power: set the laser tube max power percentage.
PWM frequency: set the PWM wave frequency. Pls set it according to
the laser machine’s features.
Back to original point speed : set the speed of backing to the original
point.
Board going speed: set the board going speed.
Back to the zero axis: set backing to the zero axis.
Water conservation: check the water conservation while checking, or
do not check.
Read the equipment parameters: read the setting parameters in the
control device.
Double head independent control: when the software detects the asynchronous
control system is enabled when the function, and vice versa is not enabled:
At the same time check the AB platform in the process of processing AB platform at
the same time work enabled, if only check one of the platform is only one beam work.
asynchronous shaft: According to the different structure of the machine, sub-double Y
double X axis to select the appropriate machine structure.
Origin Offset: After setting the asynchronous axis to the origin, whether the origin
position between the asynchronous axes is at the same horizontal position is not
necessary. If you want to set the offset value, you do not need to set it.
minimum spacing: set the asynchronous axis back to the origin, the minimum
distance between the asynchronous axis.
efficiency priority: in the cut when the graphics automatically interrupt, asynchronous
axis at the same time to improve work efficiency.
balance: both efficiency and not splicing, when the cutting graphics do not splicing
processing, will lead to another head can not process any graphics, then this time I will
interrupt the graphics splicing.
not stitching: no stitching is as long as a head can be processed, then it will not
interrupt
23