Service Support Spirit
It can explain that the arc start signal which has IHS and send by CNC is useful. If “H05”display
1, it mean CNC can not send arc start signal which has IHS.
Default of input is low level effective. User can change it on the basis of actual condition.
Parameter Parameter Default of Yellow Red
number range
parameter LED LED
Remark
L01
0 or 1
0
L01
0
The effective level of
CNC_AUTO/MANUAL.
L02
0 or 1
0
L02
0
The effective level of CNC_THC_UP.
L03
0 or 1
0
L03
0
The effective level of CNC_THC_DN.
L04
0 or 1
0
L04
0
The effective level of CNC_IHSAON.
L05
0 or 1
0
L05
0
The effective level of CNC_EXAON.
L06
0 or 1
1
L06
1
The effective level of UP_LIMIT.
L07
0 or 1
1
L08
0 or 1
0
L09
0 or 1
0
L07
1
L08
0
L09
0
The effective level of DN_LIMIT.
The effective level of testing torch
retaining cap collision signal.
The effective level of testing
proximity switch signal
Note: Default of motor limit L06L07 is Set up as 1, it means motor limit switch should be
set as shut form. User can change it on the basis of actual condition. If lifting motor do not has
limit switch, it do not connect line but they need set L06L07 as 0.
Unique Solution
WWW.ARCBRO.COM
24
    "