Service Support Spirit
Work condition
Working Temperature, 0℃~50℃. Relative Humidity, 5~95%.
Operation Voltage: 24VDC. MAX range: 21.6VDC-26.4VDC.
The THC should be installed in a cab which can provide protection from powder.
The THC should be better used in the situation without high electromagnetic radiation.
Maintenance
This controller should only be operated by trained service person.
Do not open the controller unless obtaining the authorization.
Do not let any acid or alkalescency substance to corrode the controller and the divide board.
Please turn off power supply if the controller does not need to work.
Safety notice
This THC will switch in high electromagnetic, It can hurt me if we get to touch with high
electromagnetic . Do not touch shield cable and wire when power supply is turning on.
Packing pieces must be installed in accordance with the provisions and requirements of
step.
GND must follow THC instruction.
Installation note
THC first check on electrical safety : Before THC first power, Making all port of wiring
connected, then unplug motor cable, in other words, do not connect lifting motor cable
temporarily. Then powering on. (Warning: Motor cable must be unplug before powering on,
otherwise, the reason why the lift motor has been rising (declining) is that may be received
collision signal, It can injury lifting motor)
Check whether the collision function is normal: After THC power on, check
whether the collision detection function is normal, by observing the collision indicator light to
determine whether the normal. Of the following circumstances:
Unique Solution
WWW.ARCBRO.COM
2