Service Support Spirit
“Hxx” submenu listing:
High/low level of input display in red LED. If LED display 0, input is low level.
If LED display 1, input is high level.
Parameter Parameter Yellow
number range
LED
Red LED Remark
H01
0 or 1
H01
0
The signal level condition of
CNC_AUTO/MANUAL
H02
0 or 1
H02
0
The signal level condition of CNC_THC_UP
H03
0 or 1
H03
0
The signal level condition of CNC_THC_DN
H04
0 or 1
H04
0
The signal level condition of CNC_IHSAON
H05
0 or 1
H05
0
The signal level condition of CNC_EXAON
H06
0 or 1
H06
0
The signal level condition of UP_LIMIT
H07
0 or 1
H07
0
H08
0 or 1
H08
0
H09
0 or 1
H09
0
The signal level condition of DN_LIMIT signal
The testing signal of Torch retaining cap
collision
The testing signal of proximity switch
“Lxx” submenu listing:
High level effective or low level effective of input signal is displayed in red LED. If user set it
as 0, the effective level of input is low. If user set it as 0, the effective level of input is high. When
low level is effective and the actual level of input signal is 0, it means this signal has happened.
For example, when user set“L05”as 0 and “H05”display 0, it means this signal is useful at now.
Unique Solution
WWW.ARCBRO.COM
23
    "