Service Support Spirit
P17 0-10 0.1 1
P18 0.1-1 0.1 2
P19 0-9.99 0.01 0
P20 0-20 0.1 6
Unit: Second(S). The lifting time of
P17 1.0
starting up.
Unit promoting the spear after torch has
P18 2.0
accomplished
P19 0
Unit : Second(S).Torch when arc start to
work.
Unit descending rapidly during the
P20 6.0
dual speed IHS.
Parameter explain particularly:
P00: Recovering factory parameter. P00 can display 1. If user set it as 0 and save this
parameter, all kinds of parameter in our equipment will recover factory parameter. After user
exit the submenu, they can find that P00 display 1.
P01P02P03P04: Setting manual lifting and auto lifting speed of torch. The minimum
speed is 0, the maximum speed is 50.
P05: The value of promoting arc voltage. During torch is cutting, if gun of torch go through
the crack of torch, arc voltage can rise immediately. If way of protecting arc voltage is not
used, gun of touch will descend by fast speed. In serious conditiongun of torch and
workpiece can collide by faster speed. After user set this parameter, when arc voltage
exceed the value of setting, torch height will not change. It is useful to protect torch. In
genal ,we set it as 30V.
P06: The arc voltage precision of adjusting. For example, if user set the parameter as 1V, it
means when D-value between setting arc voltage and practical arc voltage is under 1V,
torch height will not be adjusted. If user set the parameter as 3V means when D-value
between setting arc voltage and practical arc voltage is under 3V, torch height will not be
adjusted.
P07: Sensitivity coefficient. When arc voltage is changing, more and more bigger parameter
can make torch adjust become more and more faster. But if parameter is too big, torch is
easy to quiver around the balance location. If parameter is too small, torch can has slow
follow speed. In genal, we set it as 6. When user use it, it can be adjust on the basis of torch
effect.